TM 10-4520-263-12&P
0009 00
0009 00-3
Table 1. Operator Troubleshooting Procedures
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Check for soot buildup inside
the burner and especially
underneath the burner high
fire ring.
Clean out soot from under
burner high fire ring and inside
burner with a brush, rag, or
gloves. Remove all
accumulated soot.
5. Check fuel line for blockage.
Replace fuel strainer.
6. Downtube not properly
seated.
Push downtube to bottom of
burner.
7. Air bubbles in fuel line.
Shake fuel lines to dislodge
any air bubbles.
8. Air vent is not open.
Open air vent two to three
turns.
END OF WORK PACKAGE