TM 5-4520-244-14
4-16 HOW TO ADJUST MAGNETO POINTS
This task covers:
Adjustment
a.
Test
b.
INITIAL SETUP
References
Test Equipment
None
Equipment Condition
Materials/Parts
Magneto removed from heater
None
using procedure given in 414.
Magneto cover and gasket
Personnel Required
removed using procedure
1
given in 4-15.
REMARKS
ACTION
ITEM
LOCATION
ADJUSTMENT
Remove four screws.
Magneto Cover
1.
Remove magneto cover
and gasket.
Correct gap is between
Rotate until arm (6)
V-belt
2,
Measure gap
0.015 and 0.018
is on high point of
cam (9). Insert
feeler gage
Loosen screws (3).
3.
Adjust gap
Move bracket (8) to
correct gap spacing
Tighten screws (3).
4.
Secure gap
Recheck gap
Install cover and
Use four
Magneto
5.
gasket
screws
Cover
INSTALLATION
Disconnect cable at
6.
Substitute
Magneto
magneto. In its
magneto
place connect an
cable
insulated test
cable. Remove
4-24