TM 5-4520-256-14
(4)
Install four washers (2) and four screws (1) using care to line up endbells, baffles, and frame holes. Install four
nuts (21).
(5)
Install key (8) into keyway.
(6)
Connect wiring and place run capacitor into position in cover (18).
(7)
Install cover (18) and secure with two screws (17).
(8)
Connect wiring and place start capacitor into position in cover (16).
(9)
Install cover (16) and secure with two screws (15).
(10)
Install conduit box (25) and secure with two screws (22).
(11)
Install ground wire and secure with screw (26).
(12)
Install cover (24) and secure with two screws (23).
Figure 4-5. Motor Repair, Reassembly.
4-15