4-46 DISCHARGE TEMPERATURE GAUGE (CONT)
Location/Item
Action
Remarks
REMOVAL
2.
Probe and
Carefully pull probe (3) and capillary (2) through
capillary
bulkhead (4).
3. Control panel
Remove screws (5) and washers (6), and peel back
plate
control panel plate (7).
4.
Discharge tem
Lift out discharge temperature gauge (8). Carefully
perature gauge
pull capillary (2) and probe (3) through opening
(9) in plate (10).
INSTALLATlON
5. Discharge tem-
Insert probe (3) and capillary (2) through opening
perature gauge
(9) in plate (10) and bulkhead (4) and seat dis-
charge temperature housing in opening.
6. Control panel
Secure control panel plate (7) to plate (1 O) with
plate
screws (5) and washers (6).
7. Discharge tem
Complete installation as described in paragraph 4-44.
perature gauge
TESTING
8.
Discharge tem
Test as described in paragraph 4-44.
perature gauge