• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
H- 45 TYPE I (SOLID FUEL) HEATER CONT. - TM-9-4520-257-12P_157
H- 45 TYPE I (SOLID FUEL) HEATER CONT. - TM-9-4520-257-12P_160

TM-9-4520-257-12P Compressor Air Rotary Diesel Engine Driven Skid Mounted 125 cfm at 100 psi Manual
Page Navigation
  4520-01-354-1191 (TYPE II, LIQUID FUEL) NSN 4520-01-329-3451 HEATER BODY BASE DOOR LATCHES REPLACE" class="tooltip">114    115    116    117    118  119  120    4520-01-329-3451 BURNER SHELL ASSEMBLY INSPECT, SERVICE, REPAIR" class="tooltip">121    4520-01-329-3451 BURNER SHELL ASSEMBLY INSPECT, SERVICE, REPAIR CONT. - TM-9-4520-257-12P_162" class="tooltip">122    4520-01-329-3451 BURNER SHELL ASSEMBLY INSPECT, SERVICE, REPAIR CONT. - TM-9-4520-257-12P_163" class="tooltip">123    4520-01-329-3451 FLOW CONTROL BURNER HOSE REPLACE - TM-9-4520-257-12P_165" class="tooltip">124  
TM 9-4520-257-12&P                                                      0034 00 UNIT MAINTENANCE H-45 LARGE RADIANT SPACE HEATER (TYPE II, LIQUID FUEL) NSN 4520-01-329-3451 HEATER BODY BASE REPLACE 0034 00-1 INITIAL SETUP:    Tools General Mechanic’s Tool Kit (WP 0041 00, Table 2, Item 1) Materials   Absorbent Material (WP 0052 00, Table 1,   Item 1) Personnel Required One References WP 0005 00, WP 0014 00, WP 0021 00,   WP 0038 00, WP 0052 00 Equipment Condition   Heater shut down and cool (0050 00) Top heater shell removed (WP 0014 00) Burner shell assembly removed (WP 0021 00) H-45 TYPE II (LIQUID FUEL) HEATER REMOVE 1.    Turn the OFF/ON control on the fuel flow control valve (2) to the OFF position. 2.    Remove the fuel flow control valve (2) from the bracket support (8) on the heater body base (3) and set it aside on the absorbent pad. 3.    Remove the cup/cable assembly (4), and set aside.  (Refer to WP 0038 00.) REPLACE Replace the heater body base (3). INSTALL 1.    Install the cup/cable assembly (4) in the heater body base.  (Refer to WP 0038 00.) 2.    Place the burner shell assembly (5) inside the heater body base (3), and position it so that the pipe nipple (6) faces the front base heater door opening (7) and so that the flow control burner hose protrudes through the door opening (7).  (Refer to WP 0021 00.) 3.    Install the fuel flow control valve (2) into the bracket support (8) on the heater body base (3). 4.    Connect the flow control burner hose (1) to the fuel flow control valve (2).  And dispose of the petroleum absorbent mat in an authorized location. 5.    Install the top heater shell.  (Refer to WP 0014 00.)







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.