CBPK PROCEDURES cont'd
Removal cont'd - TM-9-4520-271-140068

TM-9-4520-271-14 Improved Army Space Heater (IASH) Electric Powered Multi-fuel 140 000 BTU Model H-140 Manual
Page Navigation
  37    38    39    40    41  42  43    44    45    46    47  
TM 9-4520-271-14
0007 00
CBPK PROCEDURES
Continued
Removal
1.
Loosen clamp (22) and pull outer connection of return air hose assembly (19) from return air duct (20) for access to
inner connection of return air hose assembly.
2.
Loosen clamp (21) and remove return air hose assembly (19) from return air duct (20).
3.
Loosen two clamps (17) and remove CBPK hoses (15) from blowers (18).
4.
Loosen two clamps (16) and remove CBPK hoses (15) from inlet ports of filter canisters (13).
5.
Loosen two clamps (14) and remove CBPK hoses (11) from outlet ports of filter canisters (13).
6.
Loosen two clamps (12) and remove CBPK hoses (11) from adapters (10).
7.
Remove eight screws (6), lockwashers (7), washers (8), and adapters (10). Discard lockwashers.
8.
Install two cover plates (9), eight washers (8), lockwashers (7), and screws (6). Do not tighten hardware. Slide
cover plates to closed position. Tighten hardware.
0007 00-5