TM 9-4520-271-14
0017 00
PMCS
Continued
Table 1. Unit PMCS - Continued.
EQUIPMENT
NOT READY/
ITEM TO BE
AVAILABLE
CHECKED OR
ITEM
IF:
PROCEDURE
SERVICED
INTERVAL
NO.
INTERNAL - Continued
5
Semi-
Ventilation Air Fan
annually
and Motor
Assembly
Loose, missing,
1. Fan
1.
Inspect fan for damaged or missing blades or
or damaged
loose or missing hardware.
blades or
hardware.
Loose or
2.
Inspect scroll for holes, dents, or loose or missing
damaged scroll.
hardware.
Any leaks.
2. Fuel Pump
1.
Inspect fuel pump for security and leaks
(WP 0030 00).
Missing spring
2.
Check coupling spring pin and cotter pin for
pin or cotter
security (WP 0030 00).
pin.
Loose or dam-
3. Motor
1.
Inspect motor for loose or damaged hardware.
aged hardware.
Tighten or replace hardware.
Loose, frayed,
2.
Inspect for loose connections, chafing, or exposed
or exposed
wires (WP 0033 00).
wires.
4. Base
Inspect for loose or missing hardware.
Loose base.
0017 00-7