• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Carbon Monoxide Detector CO1 Assembly Removal
Motor Contactor and Motor Overload Protector Installation

TM-9-4520-271-14 Improved Army Space Heater (IASH) Electric Powered Multi-fuel 140 000 BTU Model H-140 Manual
Page Navigation
  211    212    213    214    215  216  217    218    219    220    221  
TM 9-4520-271-14
0026 00
INSPECTION
1.
Inspect all parts for wear, cracks, corrosion, bent or broken terminals, and broken/cracked glass.
2.
Inspect all hardware for stripped or damaged threads.
REPAIR
Repair is limited to replacement of defective parts.
ASSEMBLY
Carbon Monoxide Detector CO1 Assembly Installation
1.
Install rivnuts (20) as required.
2.
Install relay board (19), four screws (18), washers (17), lockwashers (16) (item 31, WP 0062 00), and nuts (15).
3.
Carefully guide wires (13) through bracket (14) and position carbon monoxide detector CO1 (12).
4.
Install carbon monoxide detector CO1 (12), cover (11), two washers (10), lockwashers (9) (item 27, WP 0062 00), and
screws (8).
5.
Install carbon monoxide detector CO1 assembly (7), four washers (6), lockwashers (5) (item 27, WP 0062 00), and
screws (4).
6.
Install following wires (13). Remove wire marker tags.
White wire (either white wire) to terminal CO-1
Red wire to terminal CO-2
Remaining white wire and black wire to terminal CO-3
7.
Using screws (3), install following five wires (2). Remove wire marker tags.
CO-1 to relay board terminal CO-1
CO-2 to terminal CO-2
CO-3 to terminal CO-3
CO-4 to terminal CO-4
CO-5 to terminal CO-5
8.
Close side rear door (1).
0026 00-15