• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REMOVAL - TM-9-4520-271-140278
AIR PRESSURE SWITCH TESTING, REMOVAL, REPAIR, INSTALLATION, ADJUSTMENT

TM-9-4520-271-14 Improved Army Space Heater (IASH) Electric Powered Multi-fuel 140 000 BTU Model H-140 Manual
Page Navigation
  228    229    230    231    232  233  234    235    236    237    238  
TM 9-4520-271-14
0027 00
INSTALLATION
1.
Install four screws (16), eight washers (13), lens (15), bracket (14), four lockwashers (12), and nuts (11).
NOTE
Ensure that gage face is readable and straight when standing in front of the control box.
2.
Install gage (10), bracket (9), four washers (8), lockwashers (7), and nuts (6).
3.
Install bracket (5), rotate 45 degrees (800 mils), and tighten two setscrews (4).
4.
Install reducer (3), male connector (2), and tube assembly (1).
END OF WORK PACKAGE
0027 00-3/4 blank