TM 9-4520-271-14
0030 00
INSTALLATION
Continued
3.
Connect wire S4-1/L2-BLK (15) (item 60, Table 1, WP 0049 00) and solenoid valve L2 lead (16) with terminal splice
(17). Crimp terminal lug (18) onto wire. Remove wire marker tag.
4.
Connect wire TB1-8/L1-BLK (10) (item 81, Table 1, WP 0049 00) and solenoid valve L1 lead (11) with terminal splice
(12). Crimp terminal lug (13) onto wire. Remove wire marker tag.
5.
Crimp terminal lugs (13 and 18) onto two wires TB2-4/L2-BLK (8) and TB2-7/L1-BLK (7). Remove wire marker tags.
6.
Route all wires up through conduit (20).
7.
Connect wire S4-1/L2-BLK (15) to PURGE SWITCH S4 (19).
8.
Connect wire TB1-8/L1-BLK (10) to terminal board TB1 (14).
9.
Connect two wires TB2-4/L2-BLK (8) and TB2-7/L1-BLK (7) to terminal board TB2 (9).
10. Install wire ties as required.
11. Install tube assembly (6).
12. Install tube assemblies (5 and 4) (items 79 and 80, WP 0047 00).
13. Install hose assembly (3).
14. Close control panel, side front door (2), and side rear door (1).
0030 00-7