0033 00
DISASSEMBLY
1.
Remove four nuts (1), lockwashers (2), screws (3), eight washers (4), adapter (5), and gasket (6). Discard lockwashers.
2.
Remove remaining four nuts (7), lockwashers (8), washers (9), fan mount bracket (10), fan assembly (11), and gasket
(12). Discard lockwashers.
INSPECTION
Inspect parts for wear, cracks, and other damage.
REPAIR
Repair is limited to replacement of defective parts.
ASSEMBLY
1.
Install gasket (12) on fan assembly (11).
2.
Position fan assembly (11) on fan mount bracket (10).
NOTE
Leave the 3 o'clock and 9 o'clock positions empty.
3.
Install four washers (9), lockwashers (8), and nuts (7).
4.
Position gasket (6) and adapter (5) onto fan assembly (11) and secure with eight washers (4), four screws (3),
lockwashers (2), and nuts (1).
0033 00-4