  295    296    297    298    299  300  301    302    303    304    305  
TM 9-4520-271-14
0038 00
DISASSEMBLY - Continued
Remote Controller S6 and Temperature Sensor TP-1 Removal
1.
Remove front panel assembly (WP 0038 00-1).
WARNING
Avoid breathing fumes generated by soldering. Eye protection is required. Good general ventilation is
normally adequate.
2.
Cut wire ties as required.
3.
Tag and unsolder three wires (1) from thermostat control R1 terminals (2, 3, and 4).
4.
Tag and disconnect following seven wires (5) from terminal board TB4 (6). Connect remaining wires.
Yellow wire S6-P10 from TB4-8
Black wire S6-P11 from TB4-7
Red wire S6-P9 from TB4-6
Orange wire S6-P14 from TB4-5
Blue wire S6-P2 from TB4-4
White wire S6-P13 from TB4-2
Red wire S6-P1 from TB4-1
5.
Tag and disconnect white wire (5) from mode switch S8 (7) terminal 14.
6.
Remove two nuts (8), lockwashers (9), washers (10), temperature sensor TP-1 (11), and screw (12).
7.
Remove four nuts (13), washers (14), screws (15), and remote controller S6 (16).