TM 10-4520-261-12&P
SPACE HEATER ARCTIC (SHA)
0020 00
UNIT MAINTENANCE
0020 00-1/(2 Blank)
FUEL FLOW CONTROL VALVE BRACKET
THIS SECTION COVERS:
Replace
INITIAL SETUP
SHA shut-down and cool (WP 0005)
Fuel Flow Control Valve Removed from Heater
Maintenance Level
Unit
Tools and Special Tools
Materials/Parts
General Mechanic Tool Kit (WP 0025, Table 2, Item 1)
REPLACE
Remove two screws (1) securing bracket (2) to fuel flow control valve (3).
Obtain a serviceable bracket (2) and install on fuel flow control valve (3).
Install and tighten two screws (1).
END OF WORK PACKAGE
1
2
3