TM 10-4520-259-13&P
Resistance Specifications
Pri
Ohms
Sec
Ohms
110V
2-7
15-50
208V
1-5
15-50
a.
Using a multimeter check resistance between the two primary wires (1). Resistance should be
approximately 2-7 ohms. A reading of 0 or infinity indicates a defective transformer.
b.
Check resistance between one primary wire (1) and transformer housing (2). Resistance should
be infinity (indicating an open circuit). Any reading, other than infinity, indicates a defective transformer.
c.
Repeat steps a. and b. on secondary side. Resistance should be higher.
d.
If test indicates defective transformer, replace it.
INSTALL
a.
Install transformer (6) into box. Secure with two screws.
b.
Reconnect two black wires (3) from control box to transformer leads.
c.
Reconnect ignition cables (7) into secondary side of transformer.
d.
Reinstall cover (9) with six screws (8).
4-33