TM 10-4520-259-13&P
a.
Disconnect fuel supply hose (1) from elbow (2), elevate hose to allow fuel to drain back into container (3) and then
rest hose on container.
b.
Disconnect fuel return hose (4) from elbow (5), elevate hose to allow fuel to drain back into container (3) and then
rest hose on container.
c.
Remove two nuts (6), two lock washers (7), two flat washers (8), and two screws (9) from fuel filter pump bracket
(10).
d.
Disconnect fuel line (11) from fuel pump to solenoid valve (12).
e.
Disconnect elbow (13) from fuel pump.
f.
On backside of blower assembly, unscrew one screw (14) and remove cover plate with gasket (15).
g.
Tag and disconnect wires (16) and remove nut (17). Push connector (18) down, disconnecting' it from junction box
(19).
h.
Remove two capscrews (20) and lockwashers (21) securing handle assembly (22) to blower housing (23)
i.
Remove six hex head screws (24) and lockwashers (25) holding blower housing (23) to water vessel (26).
j.
Remove blower housing (23) with motor (27) attached from water vessel (26).
k.
Separate gasket (28) from blower housing (23).
INSPECT
a.
Inspect blower assembly for damage or indication of burns around the blower motor.
b.
Check for free movement of the blower.
c.
Replace any faulty components.
INSTALLATION
a.
Place gasket (28) on blower assembly (23). Set blower assembly on water vessel (26). Secure handle assembly
(22) to blower housing (23) using two capscrews (20) and lockwashers (21).
5-7