SCOPE - TM-10-4520-262-12P_15SAFETY, CARE, AND HANDLING CORROSION PREVENTION AND CONTROL (CPC) - TM-10-4520-262-12P_17EQUIPMENT CHARACTERISTICS, CAPABILITIES, AND FEATURES - TM-10-4520-262-12P_18IN-TENT CONTROLLER ASSEMBLYAIR RETURN DUCT WITH DEBRIS GRILLACCESSORY BAG BURNER ASSEMBLY - TM-10-4520-262-12P_24POWER CONTROL ASSEMBLYPOWER CONTROL ASSEMBLY (cont)ONBOARD SPARES AND TOOL.OPTIONAL ITEMS (TO ENABLE OPERATION OF HEATER INSIDE TENT)Table 1. EQUIPMENT DATA THEORY OF OPERATION THEORY OF OPERATION (cont)THEORY OF OPERATION (cont) - TM-10-4520-262-12P_33CONTROLS, INDICATORS, AND LABELS/INSTRUCTION PLATESTable 1. In-Tent Control Assembly Controls and IndicatorsGENERAL - TM-10-4520-262-12P_39Table 2. Lower Housing Assembly Controls and Indicators Table 3. SHC Labels and Instruction Plates - TM-10-4520-262-12P_41Table 3. SHC Labels and Instruction Plates - TM-10-4520-262-12P_42Table 3. SHC Labels and Instruction Plates Side View of Heater (Fuel Inlet Side)PREPARATION FOR USE SPACE HEATER CONVECTIVE (SHC) TENT WALL MODIFICATION KIT (TWMK) INSTALLATIONSPACE HEATER CONVECTIVE (SHC) TENT WALL MODIFICATION KIT (TWMK) INSTALLATION (cont) - TM-10-4520-262-12P_49SPACE HEATER CONVECTIVE (SHC) TENT WALL MODIFICATION KIT (TWMK) INSTALLATION (cont) - TM-10-4520-262-12P_50SITE SELECTION CRITERIA (OUTSIDE THE TENT)BEFORE OPERATION PMCSPositioning the Heater Outside TentFILL FUEL CAN WITH FUEL AND INSTALL FUEL CAN ADAPTER Assemble Fuel Can StandAssemble Fuel Can Stand (cont)HEATER SETUPConnect In-Tent Controller Assembly To In-Tent Controller CableRouting the In-tent Controller and Cable Through the Tent Duct Tunnel. - TM-10-4520-262-12P_59Routing the In-tent Controller and Cable Through the Tent Duct Tunnel. - TM-10-4520-262-12P_60Positioning the In-tent Controller Inside the Tent. - TM-10-4520-262-12P_61Positioning the In-tent Controller Inside the Tent. - TM-10-4520-262-12P_62CONNECT FUEL HOSE TO HEATERINSTALLING THE AIR SUPPLY AND RETURN DUCTS - TM-10-4520-262-12P_64Installing Debris Grills in Air Supply and Return DuctsInstalling The Air Supply And Return Ducts - TM-10-4520-262-12P_66Installing The Air Supply And Return Ducts - TM-10-4520-262-12P_67FINAL CHECKS BEFORE OPERATIONOPERATING THE CONVECTIVE SPACE HEATERSTARTING THE HEATERPre-purgeSTOPPING THE HEATER REFUELING WITH THE SAME FUELREFUELING WITH THE SAME FUEL (cont)REFUELING WITH A DIFFERENT FUEL REFUELING WITH A DIFFERENT FUEL (cont)REFUELING WITH A DIFFERENT FUEL (cont) - TM-10-4520-262-12P_77REFUELING WITH A DIFFERENT FUEL (cont) - TM-10-4520-262-12P_78HEATER SHUTDOWN CHARGING THE BATTERY WITH A EXTERNAL CHARGERPREPARATION FOR MOVEMENT - TM-10-4520-262-12P_81OPERATION IN EXTREME SAND, DUST, AND/OR HIGH WINDS OPERATION IN EXTREME SAND, DUST, AND/OR HIGH WINDS (cnont)OPERATION IN EXTREME RAIN OR HUMIDITY OPERATION IN EXTREME RAIN OR HUMIDITY (cont)OPERATION IN EXTREME COLD OPERATION IN EXTREME COLD (cont)NBC DECONTAMINATION PROCEDURES - TM-10-4520-262-12P_89TROUBLESHOOTING PROCEDURES - TM-10-4520-262-12P_93OPERATOR TROUBLESHOOTING PROCEDURES Table 1. Operator Troubleshooting Procedures - TM-10-4520-262-12P_96Table 1. Operator Troubleshooting Procedures - TM-10-4520-262-12P_97Table 1. Operator Troubleshooting Procedures - TM-10-4520-262-12P_98Table 1. Operator Troubleshooting Procedures - TM-10-4520-262-12P_99Table 1. Operator Troubleshooting Procedures - TM-10-4520-262-12P_100Table 1. Operator Troubleshooting Procedures - TM-10-4520-262-12P_101Table 1. Operator Troubleshooting Procedures - TM-10-4520-262-12P_102OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES SPECIAL INSTRUCTIONSTable 1. Operator Preventive Maintenance Checks and Services - TM-10-4520-262-12P_107Air Supply and Return DuctsTable 1. Operator Preventive Maintenance Checks and Services Fuel Can Stand Table 1. Operator Preventive Maintenance Checks and Services - TM-10-4520-262-12P_111In-Tent Controller Assembly CableTable 1. Operator Preventive Maintenance Checks and Services - TM-10-4520-262-12P_113Combustion Air Inlet AssemblyTable 1. Operator Preventive Maintenance Checks and Services - TM-10-4520-262-12P_115Fastener housing and keeper assembliesTable 1. Operator Preventive Maintenance Checks and Services - TM-10-4520-262-12P_117Battery PackTable 1. Operator Preventive Maintenance Checks and Services - TM-10-4520-262-12P_119Exhaust GrommetTable 1. Operator Preventive Maintenance Checks and Services - TM-10-4520-262-12P_121Onboard Spares and ToolINTRODUCTION - TM-10-4520-262-12P_123FLAME SENSOR REPLACE REPLACE - TM-10-4520-262-12P_126REPLACE (cont) - TM-10-4520-262-12P_127GLOW PLUG REPLACEGLOW PLUG REPLACE (cont)UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICESTable 1. Operator Preventive Maintenance Checks and Services - TM-10-4520-262-12P_134GENERAL - TM-10-4520-262-12P_135CLEANING AND INSPECTION OF ANTIFRICTION BEARINGS - TM-10-4520-262-12P_136IN-TENT CONTROLLER ASSEMBLY INSPECT, TEST, REPLACEREPLACE - TM-10-4520-262-12P_138IN-TENT CONTROLLER CABLE ASSEMBLY INSPECT, TEST, REPLACETEST - TM-10-4520-262-12P_140BATTERY PACK ASSY INSPECT, TEST, REPLACETEST SERVICE - TM-10-4520-262-12P_143REPLACE - TM-10-4520-262-12P_144FUEL SUPPLY QUICK DISCONNECT INSPECT, REPLACEREPLACE - TM-10-4520-262-12P_146FUEL SOLENOID VALVE AND SEDIMENT STRAINER ASSEMBLY INSPECT, SERVICE, REPLACESERVICE - TM-10-4520-262-12P_148SERVICE (cont)REPLACE - TM-10-4520-262-12P_150REPLACE (cont) - TM-10-4520-262-12P_151REPLACE (cont) - TM-10-4520-262-12P_152REPLACE (cont) - TM-10-4520-262-12P_153FUEL HOSE INSPECT, REPLACEREPLACE - TM-10-4520-262-12P_156REPLACE (cont) - TM-10-4520-262-12P_157HEATER CONTROL ASSEMBLY REPLACEREPLACE - TM-10-4520-262-12P_160WIRE HARNESS INSPECT, REPAIRREPAIR - TM-10-4520-262-12P_162POWER CONTROL ASSEMBLY REPLACEREPLACE - TM-10-4520-262-12P_164IGNITION PACK ASSEMBLY REPLACEREPLACE - TM-10-4520-262-12P_166DUST COVER ASSEMBLY INSPECT, REPLACEREPLACE - TM-10-4520-262-12P_168COMBUSTION AIR BLOWER ASSEMBLY REPLACEREPLACE - TM-10-4520-262-12P_170REPLACE (cont) - TM-10-4520-262-12P_171COMBUSTION AIR BLOWER DUCT ASSEMBLY REPLACEREPLACE - TM-10-4520-262-12P_174COMBUSTION AIR INLET ASSEMBLY REPLACE REPLACE - TM-10-4520-262-12P_176UPPER HOUSING ASSEMBLY SERVICE, REPLACE REPLACE - TM-10-4520-262-12P_178EXHAUST GROMMET REPLACEREPLACE - TM-10-4520-262-12P_180REPLACE - TM-10-4520-262-12P_181REPLACE (cont) - TM-10-4520-262-12P_182HEATED AIR BLOWER ASSEMBLY INSPECT, TEST, REPLACE REPLACE - TM-10-4520-262-12P_184REPLACE (cont) - TM-10-4520-262-12P_185REPLACE (cont) - TM-10-4520-262-12P_186FUEL PUMP REPLACEREPLACE - TM-10-4520-262-12P_188REPLACE (cont) - TM-10-4520-262-12P_189INTERNAL FUEL LINES REPLACE REPLACE - TM-10-4520-262-12P_192FLOAT ASSEMBLY REPLACE REPLACE - TM-10-4520-262-12P_194REPLACE (cont) - TM-10-4520-262-12P_195BURNER ASSEMBLY REMOVE, INSPECT, SERVICE, REPLACEREMOVE - TM-10-4520-262-12P_198REMOVE (cont) - TM-10-4520-262-12P_199REMOVE (cont) - TM-10-4520-262-12P_200INSPECT - TM-10-4520-262-12P_201SERVICE - TM-10-4520-262-12P_202REPLACE - TM-10-4520-262-12P_203REPLACE (cont) - TM-10-4520-262-12P_204REPLACE (cont) - TM-10-4520-262-12P_205THERMOELECTRIC GENERATOR (TEG) REMOVE, INSPECT, TEST, REPLACEREMOVE - TM-10-4520-262-12P_208REMOVE (cont) - TM-10-4520-262-12P_209INSPECT - TM-10-4520-262-12P_210TEST - TM-10-4520-262-12P_211REPLACE - TM-10-4520-262-12P_212REPLACE (cont) - TM-10-4520-262-12P_213REPLACE (cont) - TM-10-4520-262-12P_214HEAT EXCHANGER REMOVE, INSPECT, TEST, REPLACEREMOVE - TM-10-4520-262-12P_216REMOVE (cont) - TM-10-4520-262-12P_217SERVICE INSPECT - TM-10-4520-262-12P_219REPLACE - TM-10-4520-262-12P_220REPLACE (cont) - TM-10-4520-262-12P_221REPLACE (cont) - TM-10-4520-262-12P_222REPLACE (cont) - TM-10-4520-262-12P_223SERVICE - TM-10-4520-262-12P_225RETURN AND SUPPLY DUCTS WITH DEBRIS GRILLS INSPECT, REMOVE, REPAIRREPAIR PREPARATION FOR STORAGE OR SHIPMENT PRESERVATIONADMINISTRATIVE STORAGE REFERENCES - TM-10-4520-262-12P_235MAINTENANCE ALLOCATION CHART - TM-10-4520-262-12P_237Explanation of Columns in the MAC - TM-10-4520-262-12P_238Explanation of Columns in the MAC (cont)Table 1. MAINTENANCE ALLOCATION CHART for SPACE HEATER, CONVECTIVE Table 1. MAINTENANCE ALLOCATION CHART for SPACE HEATER, CONVECTIVE - TM-10-4520-262-12P_241Table 1. MAINTENANCE ALLOCATION CHART for SPACE HEATER, CONVECTIVE - TM-10-4520-262-12P_242REPAIR PARTS AND SPECIAL TOOLS LISTEXPLANATION OF COLUMNS IN THE REPAIR PARTS LIST AND SPECIAL TOOLS LIST WORK PACKAGES - TM-10-4520-262-12P_244Source Code - TM-10-4520-262-12P_245Source Code (contDESCRIPTION AND USABLE ON CODE (UOC) (Column (6)).EXPLANATION OF CROSS-REFERENCE INDEXES WORK PACKAGES FORMAT AND COLUMNS SPECIAL INFORMATION When P/N Is KnownFigure 1. In-tent Controller Assembly DESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_253Figure 2. Battery Assembly DESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_257Figure 3. External Fuel System ComponentsDESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_261Figure 4. Electronic Control SystemDESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_265Figure 5. Chain and Dust Cover Assembly DESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_269Figure 6. Internal Combustion Air SystemDESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_273Figure 7. Combustion Air Inlet Assembly DESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_277Figure 8. Upper Housing AssemblyDESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_281Figure 9. Exhaust Grommet DESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_285Figure 10. Duct AdaptersDESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_289Figure 11. Heated Air Blower AssemblyDESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_293Figure 12. Internal Fuel SystemDESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_297Figure 13. Burner Assembly DESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_301Figure 14. Thermoelectric Generator (TEG) DESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_305Figure 15. Heat Exchanger DESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_309Figure 16. Air Return And Supply Ducts With Debris Grill DESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_313Figure 17. Spares, Tools, and Accessories DESCRIPTION AND USABLE ON CODE (UOC) - TM-10-4520-262-12P_317NATIONAL STOCK NUMBER (NSN) INDEXPART NUMBER INDEX - TM-10-4520-262-12P_321PART NUMBER INDEX COMPONENTS OF END ITEM (COEI) AND BASIC ISSUE ITEMS (BII) LISTS - TM-10-4520-262-12P_323COMPONENTS OF END ITEM (COEI) AND BASIC ISSUE ITEMS (BII) LISTS (cont)Section II. COMPONENTS OF END ITEM - TM-10-4520-262-12P_325Section III. BASIC ISSUE ITEMS - TM-10-4520-262-12P_326ADDITIONAL AUTHORIZATION LIST (AAL) - TM-10-4520-262-12P_327EXPENDABLE AND DURABLE ITEMS LIST - TM-10-4520-262-12P_329Item Name, Part Number, (CAGEC) LUBRICATION INSTRUCTIONS - TM-10-4520-262-12P_331TORQUE LIMITS - TM-10-4520-262-12P_333Table 2. General Torque Requirements for Dry Fasteners Table 3. Locknut Breakaway Torque ValuesTable 1. Mandatory Replacement Parts GLOSSARY - TM-10-4520-262-12P_339PREPURGEThe Metric System and Equivalents - TM-10-4520-262-12P_363