TM 10-4520-262-12&P 0010 00
0010 00-15
Table 1. Operator Preventive Maintenance Checks and Services
Item
No.
Interval
Location
Procedure
Not Fully Mission
Capable If:
Item to
Check/
Service
17
Weekly
Heater Interior
Release eight fasteners (1) away from their
corresponding keeper plate (2). Remove upper
housing assembly (3). Inspect interior of heater
for:
Any dirt or debris that could be blown through
heat exchanger (4) and into the tent. Remove
dirt and debris using a clean rag. Pay special
attention to cooling fins (5) on the TEG that
could trap bits of paper or other combustibles.
Check for any evidence for leaks.
Notify Unit maintenance personnel based on
leakage class described above.
NOTE
The heater may be operated with Class I leaks
within the heater, but they must be monitored
to insure they do not get worse, pose a fire
hazard, or cause the heated air being ducted
to the tent to smell of fuel oil.
Dirt or other debris
present inside heater.
Class III Leaks
present inside heater.
18
Weekly
Electrical
Wires and
Components
Check electrical wires (6), connectors (7) and
components for any evidence of overheating,
arcing, or burning. Notify Unit maintenance
personnel.
Any wires or
connectors broken or
otherwise damaged.
19
Weekly
Burner to TEG
flange clamp
Check that the burner to TEG flange clamp
with nut (8) is secure, and provides a leak
proof seal between the burner and the TEG.
V-clamp with nut is
loose or not secure on
burner assembly and
TEG. Notify unit
maintenance.
20
Weekly
Wrap Cover
Check that the wrap cover (9) is properly
installed and tightly fastened down.
Wrap cover is loose.
Notify Unit mainte-
nance.
21
Weekly
Exhaust
Grommet
Check that black exhaust grommet (10) is
present and properly installed around the
combustion exhaust outlet (11) and is nestled
in the cutout (12) on the lower housing
assembly.
Grommet missing or
not properly installed.
Notify Unit mainte-
nance.