TM 10-4520-262-12&P 0032 00
UNIT MAINTENANCE
SPACE HEATER, CONVECTIVE
(NSN 4520-01-431-8927)
0032 00-1
DUCT ADAPTER
REPLACE
INITIAL SETUP
Tools
Materials/Parts
Tool Kit, General Mechanics (Item 1, WP 0044 00)
Personnel Required
Equipment Condition
One
Heater shut down and all advisory lights off. (WP
0006 00)
Dust covers removed. (WP 0026 00)
REPLACE
1. To remove the duct adapter (1), lift and rotate the fastener housing (2), releasing it from the
fastener keeper (3) on the upper housing assembly (4).
2. Repeat for the second fastener housing (5) and keeper on the opposite side of the duct adapter
(1).
3. Pull the duct adapter (1) from the heater body (6).
4. To install a new duct adapter (1), align it over the end of the heater body (6) and press it into
position.
5. Engage the fastener housings and keepers (2, 3 and 5) on both sides of the duct adapter (1) and
secure in place.