Figure 33. CIRCULATING PUMP MOTOR STARTER ENCLOSURE.
c. Cleaning and Inspection.
1.
Clean all parts with a cloth dampened in an approved cleaning solvent and dry thoroughly.
2.
Inspect the circulating pump motor starter for corrosion, damaged terminal posts, overheating, and other
damage.
3.
Inspect the mounting hardware for cracks, breaks, and damaged threads. Replace all defective parts.
d.
Installation. Install in reverse order of removal.
1.
Refer to Fig. 32 and install the circulating pump motor starter.
2.
Install the circulating pump motor starter heaters (Para. 48).
3.
Replace starter enclosure cover, Fig. 33.
65