Figure 13. DUAL FUEL STRAINER VALVE OPERATION.
Starting

Operating, Maintenance And Repair Parts Instructions Heater, Hot Oil, Trailer Mounted Page Navigation
  22    23    24    25    26  27  28    29    30    31    32  
img
FIGURE 14. MANUAL TRANSFER OIL VALVES (GATE VALVES)
1.
Valve A, Supply Valve
2.
Valve B, Fill Valve
3.
Valve C, Pump Suction Valve
4.
Valve D, Make-Up Valve
5.
Two sets of two Stainer Valves:
Outside Set-Valves E&F
Inside Valves-Valves G&H
VALVES OPERATING POSITIONS
1.
Valve A must be open
To open valves, turn valve handle
2.
Valve B must be closed
counter clockwise.
3.
Valve C must be open
4.
Valve D must be open
To close valves, turn valve handle
5.
One set Valves E & F or
clockwise.
Valves G & H must be open. One set must be
closed.