Figure 17. CIRCULATING PUMP AND MOTOR MOUNTING HARDWARE
Figure 19. Circulating Pump Assembly

Operating, Maintenance And Repair Parts Instructions Heater, Hot Oil, Trailer Mounted Page Navigation
  35    36    37    38    39  40  41    42    43    44    45  
img
3. Inspect the mounting hardware for cracks, breaks and damaged threads. Replace any defective
parts.
c. Installation.
1. Refer to Fig. 17 and install the pump base plate.
2. Install the circulating pump and pump coupling. (Para. 33).
3. Install the circulating pump motor (Para. 34).
To align circulating pump to circulating pump motor, the center line height of both shafts must be the
same. The coupling should be parallel when aligned on the circulating pump shaft and the circulating
pump motor shaft with no more than .015 inches offset. This would be the maximum parallel offset
allowed. The angular offset must not be more than 1 degree.
Figure 18. CIRCULATING PUMP AND
MOTOR COUPLING