TM 5-3895-377-13&P
b. Installation.
(1)
Install gasket (29) and connector body (28) with
four screws (27), lock washers (26), and nuts
(25) on junction box (5). Tighten nuts.
NOTE
Battery (small) stud of circuit breaker
connects to jumper strip.
(2)
Install circuit breaker (24) on connector (14) with
nut (23) on stud (22). Tighten nut.
(3)
Install wire (21) on stud (22) with lock washer
(20) and nut (19). Tighten nut.
(4)
Install wire (17) on stud (18) with lock washer
(16) and nut (15). Tighten nut.
(5)
Repeat steps (2) through (4) for remaining circuit
breakers.
(6)
Position gasket (13) on cover (9).
NOTE
Cover and connector are notched at
mating surfaces for alinement. Aline
notches.
(7)
Install connector (14) on cover (9) with two
screw
assemblies
(12).
Tighten
screw
assemblies.
(8)
Install ground wire (11) with screw assembly (10)
on cover (9). Tighten screw assembly.
4-99