TM 5-3895-377-13&P
5-26. PUMP MOTOR CONDUIT REPLACEMENT/REPAIR (CONT).
(3)
Remove nut (5) and elbow (6) from control box (7).
(4)
Remove four screws (8), clamps (9), and conduit section (10) from Heater (11).
b. Disassembly.
(1)
Remove elbow (1) and conduit (2) from coupling (3).
(2)
Remove adapter (4), three couplings (3), and conduit (5) from elbow (6).
5-20