TM 5-3895-377-13&P
2-14.
OPERATING PROCEDURES (CONT).
p.
Operate Fire Extinguisher.
(1)
Remove Fire Extinguisher
(a)
Pull out clamp (1) and open strap (2)
(b)
Pull fire extinguisher (3) straight out and off bracket (4)
(2)
Extinguish Fire.
(a)
Hold fire extinguisher (3) upright and
pull safety pin (5) to break plastic tie
(6)
(b)
Remove nozzle (7) from clamp 8)
(c)
Point nozzle (7) at base of fire
(d)
Press down on stop lever (9) and spray
discharge In a side-to-side motion at
base of fire
(e)
Let go of stop lever (9) when fire is out.
(f)
Replace fire extinguisher after use.
2-36