Chapter 3. OPERATOR/CREW MAINTENANCE INSTRUCTIONS
SECTION III. TROUBLESHOOTING

Maintenance Manual, Heater, Space, Multi-Fuel, With Blower, 6,000 Btu/Hr Page Navigation
  16    17    18    19    20  21  22    23    24    25    26  
img
TM 5-4520-241-14
Table 3-1. Operator/Crew Preventive Maintenance Checks and Services
NOTE
Within designated interval, these checks are to be performed in the order listed.
B - Before
Procedures
Equipment is
Item
Interval
Item To be
Check for and have repaired
Not Ready/
No.
B
Inspected
or adjusted as necessary
Available if:
NOTE
Keep heater clean by wiping with a
clean cloth.  Ensure that air inlet and
discharge outlet are free of obstruction.
1
Space heater
Make the following walk around checks:
a. Check for fuel leakage in or around heater unit.
Any
fuel
leakage
is
found.
b.  Check that the external cable connections are fully
inserted in mating receptacles with swivels tight.
NOTE
During starting and operation, check
for any unusual noises or vibration.
Check  for  improper  or  excessive
cycling,
smoking
exhaust,
and
improper combustion.  Check for fuel
leakage,  loose  hardware,  or  any
indication of a failing or defective
component.
If  suspected,  notify
organizational maintenance.
3-2 Change 1