TM 5-4520-253-13
Table 3-3. Unit Maintenance Troubleshooting Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2. Check for tripped reset circuit
breaker.
Press RESET and CIRCUIT
BREAKER buttons.
Death or serious injury could occur if pre-
cautions are not taken when maintaining this
equipment. Be sure that any power cables
are unplugged/disconnected. Be sure that the
equipment is properly grounded. Always
have another person standing by who is
trained in electric shock first aid.
Step 3. Check power source of 120 V ac.
Restore 120 V ac power or repair power source,
Step 4. Check power cable.
Disconnect power cable from POWER RECEPTACLE
heater. Check for 120 V ac between pins A and C of plug.
To replace defective power cable, disconnect power cable from 120 V ac
source.
Replace power plug as described in REMOVE/lNSTALL POWER,
FUEL PUMP, AND ROOM THERMOSTAT PLUGS, page 3-124. Connect
new power cable to 120 V ac source.
Step 5. Check POWER RECEPTACLE. Disconnect power cable and check for continuity
through pins A, C, and D of receptacle.
Replace defective receptacle as described in lNSPECT/REMOVE/lNSTALL
POWER RECEPTACLE AND EXTERNAL FUEL PUMP RECEPTACLE,
page 3-60.
3-26