TM 5-4520-256-14
3-42. LIFTING HANDLES MAINTENANCE
This Task Covers:
a. Removal
b. Inspection
c. Cleaning
d. Installation
INITIAL SETUP:
Tools Required:
Tool Kit, General Mechanics
Electric Drill
Drill Bit Set
Materials Required:
Cleaning Solvent (Item 11, Appendix E)
WARNING
Cleaning solvent, Federal Specification P-D-680, is toxic and flammable. Use only in a well-
ventilated area. Avoid prolonged breathing of fumes. Keep solvent away from flames. Do not
use in excessive amounts. Avoid skin contact.
Equipment Conditions:
Heater unit shut down and cool.
Power cable disconnected from power source.
a. Removal.
(1) Use electric drill and size 30 bit to drill out twelve rivets (1).
(2) Remove lifting handle (2).
3-134