TM 9-2540-205-24&P
TEST PROCEDURES - STEWART-WARNER AND HUPP HEATERS- Continued
ACTION
RESULTS
REMARKS
THINGS TO CHECK
7. Set control box for low heater operation. Start heater (Chapter2, Section Vi).
Start timer as soon as heater is turned on.
NOTE
If supply voltage drops to below 21 Vdc. during start, all test results maybe wrong.
Readjust for 21 to 26 Vdc. with heater on. Turn heater off, and wait at least 5 minutes
before restarting.
8. Note supply current during start cycle.
Model 10560C24-12 to 18 amps
Model 10560M-14 to 21 amps
Model MF510B, MF510C-15 to 20 amps
Model MF60A-24VI, MF60B-24V-16 to 21 amps
All models-Electrical connections
9. Measure ignitor voltage.
Model 10560C24, 10560M-1 0,0 to 11.0 Vdc.
Igniter control, voltage limiter
Model MF510B-19 to 26 Vdc.
Igniter, Igniter relay
Model 510C-17 to 18 Vdc.
Igniter, Power control
MF60A-24V
MF60B-24V-19 to 30 Vdc.
Igniter, Power control
3-194