TM 9-4520-251-14
4-36 BREATHER (CONT)
Location/Item
Action
Remarks
INSPECTION
CAUTION
Fiber disc valve is held in place by internal bracket which will be dis-
torted if excessive force is applied to fiber disc valve.
4.
Breather
5. Breather tube
grommet
6.
Breather holes
2. Fiber disc
Check fiber disc
valve
valve (4). If it is
stuck or bind-
ing, breather (2)
must be replaced.
3. Fiber disc
Check gap be-
valve gap
tween fiber disc
valve and body.
Gap should be
small enough to
prevent a 0.045
inch (1.1 mm)
wire gage (5)
from sliding in.
If gap is larger,
replace breather
(2).
Examine for
dents, bends
and distorted
tabs.
Remove breather
tube grommet
(6) and inspect
for plugging,
loose mounting,
and damage.
Examine breather
REPAIR
7. Breather
hole (7) for distortion. Inspect small holes (8) for
obstructions.
Straighten dents, bends, or bent tabs. Correct dis-
tortions in breather hole (7) where possible.
Breather tube grommet (6) must have snug fit.
4-83