TM 9-4520-257-12&P 0016 00
OPERATOR MAINTENANCE
H-45 LARGE RADIANT SPACE HEATER
(TYPE I, SOLID FUEL)
NSN 4520-01-354-1191
GRATE ASSEMBLY
INSPECT, SERVICE, REPLACE
0016 00-1
3
4
5
6
H-45 TYPE I (SOLID FUEL) HEATER
REMOVE
1. Remove the stack pipe assembly (1) from the stack flange (2) on the top heater shell (3).
2. Loosen the wing nuts on the bolt and wing nut assemblies (4) holding the top heater shell (3) to the
heater body base (5), remove the bolt and wing nut assemblies (4) from the brackets (6), and remove
the top heater shell (3). Remove the grate assembly (7).
INITIAL SETUP:
Materials
Brush (WP 0052 00, Table 1, Item 3)
Rags (WP 0052 00, Table 1, Item 7)
Personnel Required
One
References
WP 005 00
Equipment Condition
H-45 shutdown and cool (WP 0005 00)
Guy lines anchoring stack pipe untied from stakes
(WP 0005 00)
1
2
7