TM 9-4520-257-12&P 0023 00
OPERATOR MAINTENANCE
H-45 LARGE RADIANT SPACE HEATER
(TYPE II, LIQUID FUEL)
NSN 4520-01-329-3451
HOSE ASSEMBLIES
INSPECT, REPLACE
0023 00-1
H-45 TYPE II (LIQUID FUEL) HEATER
INSPECT
1. Fuel Supply Hose
a. Inspect the fuel supply hose (1) for any cracking or other deterioration that would cause the hose
to leak.
b. Check the condition of all connections (2) between the hose and the fittings (3) for a secure seal.
2. Fuel Overflow Hose
a. Inspect the overflow hose (4) for any cracking or other deterioration that would cause the hose to
leak.
b. Check the condition of the connection (5) between the hose and the quick disconnect fitting (6)
for a secure seal.
3. Flow Control Burner Hose
a. Inspect the flow control burner hose (7) for any cracking or other deterioration that would cause
the hose to leak.
b. Check the condition of the connections (8) between the hose and the fittings (9) for a secure seal.
c. If there are any cuts or damage that would cause the hose to leak, or if any of the fittings are
damaged, contact unit maintenance.
INITIAL SETUP:
Materials/Parts
Absorbent Material (WP 0052 00, Table 1, Item 1)
Personnel Required
One
References
WP 0005 00
Equipment Condition
H-45 shutdown and cool (WP 0005 00)