TM 9-4520-257-12&P 0026 00
OPERATOR MAINTENANCE
H-45 LARGE RADIANT SPACE HEATER
(TYPE II, LIQUID FUEL)
NSN 4520-01-329-3451
FUEL FLOW CONTROL VALVE
INSPECT, SERVICE
0026 00-1
H-45 TYPE II (LIQUID FUEL) HEATER
REMOVE
1. Outside the tent, remove the fuel can from the fuel can stand assembly, and place the fuel can
upright on level ground. (Refer to WP 0005 00).
NOTE
The fuel flow control inlet fitting (5) is the fitting that sticks out of the left
side of the fuel flow control valve (1) closest to the heater body base (11)
when the fuel flow control valve (1) is mounted on the bracket holder (10)
on the heater body base (11).
The fuel overflow fitting (7) is the fitting that sticks out of the left side of
the fuel flow control valve (1) furthest from the heater body base (11)
when the fuel flow control valve (1) is mounted on the bracket holder (10)
on the heater body base (11).
The flow control outlet fitting (9) is the only fitting on the bottom of the
fuel flow control valve (1) when the fuel flow control valve (1) is mounted
on the bracket holder (10) on the heater body base (11).
2. Inside the tent, place a piece of absorbent material under the fuel flow control valve (1), and turn the
fuel OFF/ON control (3) on the fuel flow control valve (1) to OFF.
3. Disconnect the fuel supply hose (4) from the fuel flow control inlet fitting (5).
4. Disconnect the fuel overflow hose (6) from the fuel overflow fitting (7).
5. Disconnect the flow control burner hose (8) from fuel flow control outlet fitting (9).
6. Remove the fuel flow control valve (1) from the bracket holder (10) on the heater body base (11).
INITIAL SETUP:
Materials/Parts
Absorbent Material (WP 0052 00, Table 1, Item 1)
Rags (WP 0052 00, Table 1, Item 7)
Personnel Required
One
References
WP 0005 00
Equipment Condition
H-45 shutdown and cool (WP 0005 00)