TM 9-4520-257-12&P 0008 00
0008 00-3
Table 2. H-45 Type II (Liquid Fuel) Heater Troubleshooting (Operator)-continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Check fuel line from fuel can to
fuel flow control for air bubbles.
Open primer valve and shake
hose assembly to purge air
bubbles until a strong flow is
achieved.
Accumulation of soot in stack
pipe.
Clean stack pipe in accordance
with WP 0020 00.
Fuel selector control set
incorrectly.
Follow the procedures in
WP 0005 00, Starting the H-45
Type II (Liquid Fuel) Heater) to
determine the correct setting.
Check if heater is being overfired
or underfired.
If heater is overfired, turn flow
adjustment knob on fuel flow
control counterclockwise to
reduce flow rate. If underfired,
turn knob clockwise to increase
flow rate.
Check that stack pipe sections
are assembled and properly fitted
together.
Reassemble any opened pipe
sections.
Tightly reconnect all pipe
sections.
Check for accumulation of soot in
burner cap assembly and burner
shell assembly components.
Clean burner cap assembly.
Refer to WP 0021 00.
Clean burner shell assembly.
Refer to WP 0021 00.
2. Heater does not operate
properly.
Make sure that automatic vent on
gravity feed adaptor is not
blocked with ice or snow
Clear obstructions from gravity
feed adaptor vent
Check to see if fuel setting is too
high.
Turn fuel setting down.
Check to see if fuel selector is on
the correct setting.
Rotate fuel selector knob to
correct fuel type being used.
Check to see if draft doors are
open.
Open draft doors.
Check stack pipe sections for
cracks.
Replace cracked sections.
Check stack for proper number of
stack pipe sections.
Failure to use all six stack pipe
sections will adversely affect
heater performance, increase
soot buildup, and increase
maintenance. Always use all six
sections.
3. Excessive dark smoke
Check stack for proper fit
between stack pipe sections.
Push stack pipe sections
together.