TM 9-4520-258-14
Table 4-1. Unit Preventive Maintenance Checks And Services.
Location
Not Fully
Item
No.
Interval
Item to
Check/Service
Procedure
Mission
Capable If:
8
1000 hrs
INTERNAL
___________
c.
Burner -
continued
(1) Nozzle
(2) Electronics
(3) Fire Ring
Remove burner assembly from heat exchanger (refer to
para 4-33).
Remove three setscrews (1) and pull burner (2) from
housing (3).
Remove nozzle from burner.
Inspect for cleanliness and condition of threads.
Remove filter and discard.
Install new filter on nozzle and install nozzle snugly on
burner, do not overtighten.
Inspect for cleanliness and secure mounting.
Check for signs of pitting, burning or cracks.
Inspect for cleanliness and secure mounting.
Inspect for burning or other signs of damage.
I
Dirty filter.
Cracks found in
electronics.
4-22