TM 9-4520-271-14
0002 00
EQUIPMENT DATA
Table 1 lists equipment data for the ASH. Table 2 lists types of fuel for the ASH. Table 3 lists fuel pressure settings for
the ASH.
Table 1. Equipment Data.
EQUIPMENT
DATA
General information
H-140
Model
60300-100
Part number
National Stock Number (NSN)
Dimensions
59 in. (149.9 cm)
Length
40 in. (101.6 cm)
Width
33 in. (83.8 cm)
Height
12 in. (30.5 cm)
Diameter of air duct connectors
25 ft (7.62m)
Remote control box cable
25 ft (7.62m)
Power cable assembly
25 ft (7.62m)
External fuel hose
12 in. diameter x 15 ft (30.5 cm diameter x 4.57m)
Supply and return air hose assemblies
Weight
360 lbs (163 kg)
Operating temperature range
60 F to +100 F (51 C to +38 C)
150,000 BTU/hr at sea level; 140,000 BTU/hr at 4,000 ft
(1,220m) elevation
Electrical input
120 Vac; 50/60 Hz; single-phase, grounded; 1,200W (10A)
Rated airflow
1,000 cfm (28.3 cubic meters per minute) sea level
Fuel capacity
14 gal (53L) internal fuel tank; connection for single hose,
external fuel source
Types of fuel
See Table 2.
Fuel pressure settings (elevation at 50/60 Hz)
See Table 3.
0002 00-9