TM 9-4520-271-14
0037 00
ASSEMBLY
Continued
Flame Detector Installation
1.
Insert wire end of flame detector (20) up through bottom hole of heat exchanger shell (26) and through bottom hole of
heat exchanger (24).
2.
Install grommet (25) into heat exchanger shell (26).
3.
Install braided shield (22) and clamp (21) onto sleeve (23).
4.
Slide clamp (17) onto tube (19), install flame detector (20) into tube, and slide braided shield (18) over tube. Tighten
clamp.
5.
Route wires (10 and 9) from flame detector (20) along wire bundle and guide wires up through conduit (12).
6.
Install braided wire (15), lockwasher (14) (item 23, WP 0062 00), and nut (13) onto ground stud (16).
7.
Connect wire TB3-2? D1-YEL (10) and wire TB3-1? D1-YEL (9) to TB3 (11). Remove wire marker tags.
8.
Install wire ties as required.
9.
Close side rear door (8).
0037 00-8