Stowing the operator control box. To prepare the LCFH for movement, stow the operator control box
(1) by securing the CO detector. Close the cover (2) on the side of the operator control box (1) and
secure by tightening the thumb screw (3).
Remove the operator control box from its hanging location and pass the panel and its connecting cable
under the wall of the shelter.
Stow the operator control box in its docking location by aligning the upper retaining rail (4) on the panel
with the mating rail on the cabinet. Secure the operator control box in place by engaging the turn-key
latch (5) on the tab (6) at the lower right corner of the operator control box.
Wrap the operator control box cable (7) neatly around the operator control box handles (8). Tuck the last
portion of the cable under the cable already secured to prevent the cable from unwinding.
Close the outer operator control box cover (9).