TM 9-4520-272-14&P
0010 00
Table 1. Operator Preventive Maintenance Checks and Services.
ITEM INTERVAL LOCATION
PROCEDURE
NOT FULLY MISSION
NO.
CAPABLE IF:
ITEM TO
CHECK/SERVICE
12
During
Fuel lines
Any Class III leaks that
WARNING
are observed. Heater
Hearing protection should be worn
can be operated with
when performing any troubleshooting
Class I or Class II
or maintenance function requiring that
leaks; however, note
the heater be operating with any of the
all leaks and notify unit
access panels open. Failure to wear
maintenance.
ear protection could result in hearing
loss or damage.
Do not place hands or inside heater
while heater is operating. Placing
hands inside heater when it is
operating may cause serious injury or
death.
Inspect all fuel lines in heater and ensure
that there are no leaks.
13
During
Oil leaks
Any Class III leaks that
WARNING
are observed. Heater
Hearing protection should be worn
can be operated with
when performing any
Class I or Class II
troubleshooting or maintenance
leaks; however, note
function requiring that the heater be
all leaks and notify unit
operating with any of the access
maintenance.
panels open. Failure to wear ear
protection could result in hearing
loss or damage.
Do not place hands inside heater
while heater is operating. Placing
hands inside heater when it is
operating may cause serious injury
or death.
Inspect interior of heater and ensure that
there are no oil leaks.
0010 00-11