TM 9-4520-271-14
0021 00
REMOVAL
Continued
DISASSEMBLY
1.
Remove six parts of gasket (6).
2.
Mark location of insulation (7, 8, and 9) and remove as required.
REPAIR
Repair is limited to replacement of defective parts.
ASSEMBLY
WARNING
Rubber adhesive is flammable. Keep away from open flames or other sources of ignition. Avoid breathing
fumes from adhesive. Good general ventilation is normally adequate. Avoid skin contact with adhesive.
1.
If insulation has been removed, apply rubber adhesive to insulation (9, 8, and 7) (items 39, 41, and 40, WP 0047 00).
2.
Install six parts of gasket (6) (items 45 thru 50, WP 0047 00).