TM 9-4520-271-14
0035 00
ASSEMBLY
1.
Install six rivnuts (35) onto mounting plate (25).
2.
Install grommet (34) onto mounting plate (25).
3.
Install RF filter (33), braided shield (17), two lockwashers (32) (item 22, WP 0062 00), and screws (31).
4.
Install gasket (30) (item 88, WP 0047 00) onto mounting plate (25).
5.
Install two hollow studs (29) onto high-tension leads (28).
6.
Slide two insulation sleevings (27) over high-tension leads (28) and install high-tension leads onto ignition transformer
(24).
7.
Position and secure insulation sleevings (27) over high-tension leads (28) and ignition transformer (24).
8.
Install ground wire (21) and screw (26) onto ignition transformer (24).
9.
Install ignition transformer (24) into mounting plate (25).
10. Install ground wire (23), screw (22), ground wire (21), two washers (20), lockwasher (19) (item 27, WP 0062 00), and
nut (18).
11. Install two braided shields (17) (item 89, WP 0047 00) onto wires as shown.
12. Connect two wires with wire splices (16). Remove wire marker tags.
13. Install two rivnuts (15) onto bracket (9).
14. Install gasket (14) (item 91, WP 0047 00) and EMI gasket (13) (item 92, WP 0047 00) onto lid (10).
15. Install gasket (12) (item 90, WP 0047 00), capacitor (11), bracket (9), two lockwashers (8) (item 22, WP 0062 00), and
screws (7) onto lid (10).
16. Install capacitor assembly (6), four washers (5), lockwashers (4) (item 27, WP 0062 00), and screws (3).
17. Connect two wires (1) onto capacitor (2). Remove wire marker tags.
0035 00-5