CAUTION
I
WHEN FIRING THIS WATER HEATER WITH GASOLINE, COMBINE ONE (1) QUART
OF OE-30 WITH EACH FIVE (5) GALLONS OF GASOLINE FOR INTERNAL
LUBRICATION OF THE FUEL PUMP.
II
WHEN WATER HEATER IS OPERATED WTH GASOLINE AND IS TO REMAIN
UNUSED FOR FIVE(5) DAYS OR MORE, COMPLY WITH THE FOLLOWING
INSTRUCTIONS:
1.
REMOVE FUEL PUMP STRAINER COVER, DRAIN FREE OF GASOLINE,
WIPE DRY, REINSTALL STRAINER COVER.
2.
OPERATE FUEL PUMP, DRAW ONE (1) QUART OF OE-30 INTO FUEL
PUMP THRU FUEL INTAKE LINE. SHUT FUEL PUMP OFF.
3.
REPEAT ABOVE PROCESS FOR EACH EXTENDED SHUT DOWN
PERIOD.
III
AFTER SHUT DOWN IN FREEZING TEMPERATURE DRAIN ALL WATER FROM
FILTERS, TANKS, PUMPS, AND HOSE. LEAVE DRAIN VALVES OPERN,
INSPECT UNIT TO INSURE ALL WATER HAS BEEN DRAINED.
IV
WHEN USED IN AREAS WHERE SCHISTOSOMIASIS IS PREVALENT, THIS UNIT
SHOULD BE OPERATED IN CONJUNCTION WITH WATER TREATMENT
PROCEDURES APPROVED BY THE MAJOR COMMAND SURGEON.
(NAVMED P-5052-6A/AFP 16-1-1-7)
Figure 2-8. Decals and Instruction Plates (Sheet 3 of 5)
2-29