TM 10-4520-259-13&P
2-15.
PREPARATION FOR MOVEMENT. (Fig. 2-9) To prepare the water heater for movement, follow the
procedures below.
a.
Perform shutdown procedures as described in paragraph 2-13.
WARNING
Do not attempt to move the water heater before disconnecting
all electrical power from the heater. Death or serious injury may
result.
b.
As time and circumstances allow, perform operator PMCS "After" services described in Section
II.
c.
Clean and dry the water heater and its auxiliary equipment as described in paragraph 2-5.
d.
Disconnect power cable (1) from receptacle (2).
e.
(M-80) Disconnect smokestack (3).
f.
(M-85) Disconnect exhaust ducts (4).
Figure 2-9. Preparation For Movement
2-32