TM 10-4520-261-12&P
SPACE HEATER ARCTIC (SHA)
0018 00
UNIT MAINTENANCE
0018 00-1
FUEL FLOW CONTROL VALVE FUEL STRAINER
THIS SECTION COVERS:
Service and Replace
INITIAL SETUP
SHA shut-down and cool (WP 0005)
Maintenance Level
Unit
Tools and Special Tools
Materials/Parts
General Mechanic Tool Kit
Strainer (WP 0046, Table 1, Item 6)
(WP 0025, Table 2, Item 1)
Gasket, Cork (WP 0046, Table 1, Item 7)
Solvent, Dry Cleaning (WP 0046, Table 1, Item 2)
REMOVE
Remove strainer (1) from fuel flow control valve (2) by rotating counter-clockwise with a screwdriver.
Remove cork gasket (3).
INSPECT
Inspect strainer (1) for sediment or other obstructions. If unserviceable, obtain a serviceable strainer (1),
skip CLEAN procedures, and proceed to REPAIR.
CLEAN
If necessary, clean the strainer (1) to remove dirt or other obstructions.
WARNING!
Fire and Injury To Personnel
Dry Cleaning Solvent P-D-680 is dangerous to personnel and property,
and has a low flash point (100 to 138 degrees Fahrenheit [38 to 59
degrees Celsius]). Avoid skin contact by wearing rubber gloves and do
not use the solvent near open flame or in areas where temperatures
exceed the flash point.
Mix Dry Cleaning Solvent to specifications on product container.
Allow strainer (1) to soak in the solution to loosen sediment.
Remove strainer (1) from solution, blow off excess and allow to air dry.