TM 10-4520-262-12&P 0020 00
0020 00-2
SERVICE
1. To clean and service the sediment strainer (1), loosen the knurled nut (2) at the base of the
sediment strainer bowl (3).
2. Rotate the bale (4) to the right and upward while supporting the bowl (3).
3. Rock the bowl (3) slightly and remove it from the sediment strainer top assembly (5).
4. Empty the fuel from the bowl (3) into an approved container and discard. Do not empty the fuel
into a fresh fuel supply.
5. Remove the gasket (6) and screen (7) from the sediment strainer top assembly (5) and discard in
an approved manner.
6. Install a new gasket (6) and screen (7) in position on the sediment strainer top assembly (5).
7. Replace the bowl (3) under the sediment strainer top assembly (5).
8. Rotate the bale (4) downward and center under the bowl (3).
1
2
3
4
4
4
4
5
6
8
7