TM 10-4520-263-12&P
0001 00
SPACE HEATER SMALL (SHS)
GENERAL INFORMATION
0001 00-2
MAINTENANCE FORMS RECORDS AND REPORTS.
Department of the Army forms and procedures used for equipment maintenance will be those prescribed
by DA PAM 738-750, Functional Users Manual for The Army Maintenance Management System
(TAMMS) (Maintenance Management Update).
REPORTING EQUIPMENT IMPROVEMENT RECOMMENDATIONS (EIRs).
If your SHS needs improvement, let us know. Send us an EIR. You, the user, are the only one who can
tell us what you dont like about your equipment. Let us know why you dont like the design or
performance. Put it on an SF368 Product Quality Deficiency Report . Mail it to Commander, U.S. Army
Soldier and Biological Chemical Command, ATTN: AMSSB-RIM-E(N), Kansas Street, Natick, MA 01760-
5052. We will send you a reply.
SAFETY, CARE, AND HANDLING
General Safety. While in operation, the heater presents a potential burn and carbon monoxide hazard.
Proper precautions should be observed while operating the heater.
Observe all warning and caution notes that appear before each maintenance operation. Refer also to the
Warning Summary at the beginning of this technical manual.
CORROSION PREVENTION AND CONTROL (CPC).
Corrosion Prevention and Control (CPC) of Army materiel is a continuing concern. It is important that any
corrosion problems with this item be reported so that the problem can be corrected and improvements can
be made to prevent the problem in future items.
While corrosion is typically associated with rusting of metals, it can also include deterioration of other
materials, such as rubber or plastic. Unusual cracking, softening, swelling or breaking of these materials
may be a corrosion problem.
If a corrosion problem is identified, it can be reported using SF 368, Product Quality Deficiency Report.
Use of key words such as corrosion, rust, deterioration, or cracking will ensure that the information
is identified as a CPC problem. This form should be submitted to the address specified in DA PAM 738-
750.
DESTRUCTION OF ARMY MATERIEL TO PREVENT ENEMY USE.
For procedures to destroy this equipment to prevent its use by the enemy, refer to TM 750-244-3,
Procedures for Destruction of Material to Prevent Enemy Use.
NOMENCLATURE CROSS-REFERENCE LIST.
Common Name
Official Name
SHS
Space Heater Small
Burner Rate Control
Regulating Float Valve
ON/OFF Control Valve
Fuel Shut Off Valve
Tent
Soldier Crew Tent