TM 10-4520-263-12&P
0002 00
0002 00-2
Fuel Quick Disconnect (22). Allows an external fuel source to be connected to the Space Heater Small,
bypassing the internal fuel tank and substantially increasing run time.
Overflow Hose (23). The Overflow Hose (23) is attached to a barb fitting located under the regulating
float valve (19) and allows any overflow fuel to be conducted out of the tent.
Heat Shield (24). A perforated heat shield (24) surrounds the Space Heater Small and prevents
accidental contact with the hot burner assembly parts during heater operation.
Fuel strainer (25). The fuel strainer (25) is located between the fuel tank and the regulating float valve
and acts to filter any dirt or other foreign matter that may be in the fuel supply.
Tent Collar Assembly (26). The tent collar assembly (26) is installed on the inner roof opening (27) of the
tent and effectively reduces the diameter of the roof opening (27), thereby providing a weathertight pass-
through for the stack assembly (2).
Stack Lock (28). The stack lock (28) is a sliding bracket located on the top of the fuel tank (6). The stack
lock (28) slides over the fuel cap (7) when the stack assembly (2) is in position, preventing refueling of the
heater inside the tent.
1
2
3
4
8
19
20
21
23
24
6
26