Ultraviolet (UV) Scanner
Figure 39. IGNITION SYSTEM

Operating, Maintenance And Repair Parts Instructions Heater, Hot Oil, Trailer Mounted Page Navigation
  61    62    63    64    65  66  67    68    69    70    71  
img
Figure 38. ULTRAVIOLET (U.V.) CELL.
54. Ignition Transformers and Bussbars
a.
Removal. Refer to Fig. 39 and remove the ignition transformer and ignition cables.
WARNING: DO NOT SERVICE ANY ELECTRICAL EQUIPMENT WHILE ELECTRICAL SUPPLY IS
CONNECTED. TURN ALL ELECTRIC POWER OFF. IGNITION TRANSFORMER HAS 120
VOLTS PRIMARY CONNECTIONS, WITH 10,000 VOLTS SECONDARY TO GROUND.
1.
Remove 2 screws on ignition transformer; tag and disconnect electrical wires, remove electrical fittings.
2.
Remove 2 screws from burner cover plate; remove plate.
3.
Pull ignition wires from ignition transformer.
4.
Remove 2 nuts from mounting studs; remove ignition transformer.