TM 5-3895-377-13&P
Table 4-2. Unit Troubleshooting - CONT.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL (CONT)
4.
BURNER DOES NOT OPERATE (CONT).
Step 6.
Using a multimeter, check for 120 Vac at terminals T1 and T2 of burner relay.
If 120 Vac are not present at both terminals, relay is defective. Replace relay page 4-185).
Step 7.
Press RESET button on burner, and check for 120 Vac at pin 7 on thermostats.
If voltage is not present, replace thermostats (page 4-188).
If problem persists, go to Burner Does Not Fire (page 4-48).
4-25