TM 5-3895-377-13&P
4-31.
TEMPERATURE GAGE REPLACEMENT (CONT).
NOTE
Mark position of connector prior to
removal.
(4)
Disconnect connector (9) from temperature
gage (10).
(5)
Remove four nuts 11), mounting bezel (12),
and temperature gage (10) from panel 8).
b.
Installation.
(1)
Install mounting bezel (12) and temperature
gage ( 10) on panel (8) with four nuts ( 11)
and tighten nuts.
(2)
Connect connector (9 to temperature gage
(10).
(3)
Lift panel (8) to upright position and install ten screws (7) and nuts (6).
(4)
Tighten two screws (7), nuts (6), two screws (5), and nuts (4).
(5)
Close cover (3), reposition clamps (2), and tighten screws (1).
NOTE
Follow-on Maintenance. Remove wheel chocks (page 2-35).
END OF TASK
4-64