TM 5-3895-377-13&P
4-69.
20 AMP CIRCUIT BREAKER REPLACEMENT (CONT).
NOTE
Tag and mark all wires prior to removal.
(4) Loosen two screws (9) and remove two wires (10) from circuit breaker (11).
(5) Remove screw (12) and clamp (13) from backplate (14).
(6) Remove circuit breaker (11) from backplate (14).
b.
Installation.
(1) Position circuit breaker (11) in holddown bracket on backplate (14).
(2) Install clamp (13) and screw (12) on circuit breaker (11) and in backplate (14). Tighten screws.
(3) Install two wires (10) in circuit breaker (11) and tighten two screws (9).
4-172